CONTROLLER PROFIBUS 5 100A 24VDC – LTMR100PBD Schneider Electric

Rp25.692.876

Intelligent (Programmable) Motor Protection Relay – Schneider Electric (LTMR (TeSys T)) – Rated current 5-100A – Power supply (DC) 24V – 3 integrated measurement CTs – Profibus communication

Stok 19

SKU: LTMR100PBD Kategori: ,

Deskripsi

Range name TeSys
Sub-range name LTMR (TeSys T)
Rated Voltage (AC) – Phase-to-phase (50-60Hz) 690 V
Supply voltage (DC) 24 V
Rated current 5-100 A
Minimum current 5 A
Maximum current 100 A
Poles 3 Pole(s)
Compliant with standard(s) EN 60947-4-1
IACS E10
IEC 60947-4-1
UL 508
CSA C22.2 No 14
Analog inputs quantity (Temperature sensor probe) 1
(Ground fault measurement CT) 1
Digital inputs quantity 6
Digital outputs quantity 1 x NC contact
4 x NO contacts
Connection type 3 measurement current transformers
(control circuit) Screw-clamp
Technology used in component Electronic (Programmable)
Protection function Thermal overload (1 alarm; 1 trip) thermal protection of motor by monitoring current consumption
Motor temperature (1 alarm; 1 trip) thermal monitoring of the motor using temperature probes (winding; paper…). Up to 3 sensors in series.
Phase imbalance (1 alarm; 1 trip) monitors the symmetry of currents. To be used for imbalance < 80 % of the average current.
Phase failure (1 alarm; 1 trip) monitors the symmetry of currents. To be used for imbalance < 80 % of the average current.
Phase reversal (1 alarm; 1 trip) signals when the phase sequence is different from the defied sequence (motor running).
Long starting time (1 alarm; 1 trip) monitors the motor starting time.
Locked rotor (1 alarm; 1 trip) locking detected by a sudden increase in current after the start phase.
Minimum current load limit variation (1 alarm; 1 trip) monitors motor load through variations of current around preset thresholds.
Maximum current load limit variation (1 alarm; 1 trip) monitors motor load through variations of current around preset thresholds.
Earth fault (1 alarm; 1 trip) signals internal insulation faults by vectorial summing of external currents via earth fault toroid.
Frequent starting (inhibits start) Protects the motor against overheating due to frequent starting.
Measurement function (Measurement) Current/Phase 0.08-1000A
(Measurement) earth current 0.1633 x CT ratio
(Measurement) Average current 0.08-1000A
(Measurement) Current imbalance between phases 0-200%
(Measurement) Thermal capacity level 0-200%
(Measurement) Motor temperature rise 0-6500 Ohm
Protection settings (Thermal overload) Class 5; 10; 15; 20; 25;30
(Thermal overload) Inverse thermal definite time
(Motor temperature) PTC binary
(Motor temperature) BTC/NTC analogue 20-6500 Ohm
(Phase imbalance) 10-70% I average 0.2-20s
(Phase failure) 0.1-30s
(Phase reversal) A-B-C
(Phase reversal) A-C-B
(Long starting time) 100-800% of FLC – 1-200s
(Locked rotor) 100-800% of FLC – 1-30s
(Minimum current load limit variations) 30-100% of FLC – 1-200s
(Maximum current load limit variations) 20-800 of FLC – 1-250s
(Earth fault) internal 50-500% min FLC – 0.5-25s
(Earth fault) external 0.02-10A – 0.1-25s
(Frequent starting) 0-999.9s
Communication protocol Profibus
Functions (Control modes) Local via terminal block; Local via HMI terminal; Remote via network
(Operating modes) Overload; Independent; Reverser; 2-step; 2-speed; “Custom” mode
(Fault management) Manual reset; Automatic reset; Remote reset
(Fault statistics) Protection fault counters
(Fault statistics) Protection alarm counters
(Fault statistics) Diagnostic fault counters
(Fault statistics) Motor control function counters
(Fault statistics) Motor control function counters
(Fault statistics) Fault history
(Fault diagnostics) Internal watchdog fault
(Fault diagnostics) Controller internal temperature
(Fault diagnostics) Temperature sensor connection
(Fault diagnostics) Current connection
(Fault diagnostics) Voltage connection
(Fault diagnostics) Motor control commands (start; stop; run check back and stock check back)
(Fault diagnostics) Control configuration checksum
(Fault diagnostics) Loss of communication
(Motor statistics) Number of motor control commands (O.1/O.2 starts)
(Motor statistics) Operating time
(Motor statistics) Number of starts/hour
(Motor statistics) Last start I max.
(Motor statistics) Duration of last start
(Thermal overload statistics) Time to trip
(Thermal overload statistics) Time to restart
(System operating statistics) Run; On; Start; alarm; fault
Primary brand Schneider Electric
Secondary brand Telemecanique